Warning: The magic method Theme_Demo_Import::__wakeup() must have public visibility in /home/spacehos/public_html/prasha/wp-content/plugins/theme-demo-import/inc/class-tdi-main.php on line 74

Warning: Cannot modify header information - headers already sent by (output started at /home/spacehos/public_html/prasha/wp-content/plugins/theme-demo-import/inc/class-tdi-main.php:74) in /home/spacehos/public_html/prasha/wp-includes/rest-api/class-wp-rest-server.php on line 1902

Warning: Cannot modify header information - headers already sent by (output started at /home/spacehos/public_html/prasha/wp-content/plugins/theme-demo-import/inc/class-tdi-main.php:74) in /home/spacehos/public_html/prasha/wp-includes/rest-api/class-wp-rest-server.php on line 1902

Warning: Cannot modify header information - headers already sent by (output started at /home/spacehos/public_html/prasha/wp-content/plugins/theme-demo-import/inc/class-tdi-main.php:74) in /home/spacehos/public_html/prasha/wp-includes/rest-api/class-wp-rest-server.php on line 1902

Warning: Cannot modify header information - headers already sent by (output started at /home/spacehos/public_html/prasha/wp-content/plugins/theme-demo-import/inc/class-tdi-main.php:74) in /home/spacehos/public_html/prasha/wp-includes/rest-api/class-wp-rest-server.php on line 1902

Warning: Cannot modify header information - headers already sent by (output started at /home/spacehos/public_html/prasha/wp-content/plugins/theme-demo-import/inc/class-tdi-main.php:74) in /home/spacehos/public_html/prasha/wp-includes/rest-api/class-wp-rest-server.php on line 1902

Warning: Cannot modify header information - headers already sent by (output started at /home/spacehos/public_html/prasha/wp-content/plugins/theme-demo-import/inc/class-tdi-main.php:74) in /home/spacehos/public_html/prasha/wp-includes/rest-api/class-wp-rest-server.php on line 1902

Warning: Cannot modify header information - headers already sent by (output started at /home/spacehos/public_html/prasha/wp-content/plugins/theme-demo-import/inc/class-tdi-main.php:74) in /home/spacehos/public_html/prasha/wp-includes/rest-api/class-wp-rest-server.php on line 1902

Warning: Cannot modify header information - headers already sent by (output started at /home/spacehos/public_html/prasha/wp-content/plugins/theme-demo-import/inc/class-tdi-main.php:74) in /home/spacehos/public_html/prasha/wp-includes/rest-api/class-wp-rest-server.php on line 1902
{"id":3794,"date":"2021-08-26T06:19:09","date_gmt":"2021-08-26T06:19:09","guid":{"rendered":"https:\/\/spacehost.in\/prasha\/?page_id=3794"},"modified":"2021-09-03T09:24:41","modified_gmt":"2021-09-03T09:24:41","slug":"products-3-16","status":"publish","type":"page","link":"https:\/\/spacehost.in\/prasha\/index.php\/products-3-16\/","title":{"rendered":"DG 5Kva-30Kva"},"content":{"rendered":"\n

<\/p>\n\n\n\n

\"\"<\/figure><\/div>\n\n\n\n
\"\"<\/figure>\n\n\n\n

<\/p>\n\n\n\n

GENERATOR SPECIFICATIONS-5 kVA<\/strong><\/p>\n\n\n\n

<\/tr>
Power Rating (KVA)<\/td>5<\/td><\/tr>
Electric Power (kWe)<\/td>4<\/td><\/tr>
Rated Current (Amp)<\/td>20.85<\/td><\/tr>
DG Size L x W x H (mm)<\/td>1050 x 580 x 900<\/td><\/tr>
DG Weight approx. (kg)<\/td>290<\/td><\/tr>
Fuel Tank Capacity (Ltr)<\/td>12<\/td><\/tr>
Battery Capacity (AH)<\/td>35<\/td><\/tr>
System DC Voltage (Volt)<\/td>12<\/td><\/tr>
ENGINE SPECIFICATIONS<\/u><\/strong><\/td><\/tr>
Engine Model<\/td>AL418DG1<\/td><\/tr>
Engine Rated kW\/Engine Rated HP<\/td>5.5\/7.5<\/td><\/tr>
Aspiration<\/td>NA<\/td><\/tr>
No. of cylinders & configuration<\/td>Single, Vertical<\/td><\/tr>
Bore x Stroke<\/td>86 x 72<\/td><\/tr>
Displacement<\/td>0.418<\/td><\/tr>
Compression ratio<\/td>20:01<\/td><\/tr>
Lube Oil Capacity approx. (Ltr)<\/td>1.65<\/td><\/tr>
Coolant Capacity approx. (Ltr)<\/td>Air Cooled<\/td><\/tr>
Governing Class<\/td>A1<\/td><\/tr>
Governer Used<\/td>Mechanical<\/td><\/tr>
Oil Change Period<\/td>150 Hrs or 3 Month<\/td><\/tr>
Lube Oil specification<\/td>Gulf Leypower XLL Diesel Engine Oil<\/td><\/tr>
Alternator<\/td>230 V**<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n

<\/p>\n\n\n\n

GENERATOR SPECIFICATIONS-10\/15 kVA<\/strong><\/p>\n\n\n\n

<\/tr>
Power Rating (KVA)<\/td>10\/15<\/td><\/tr>
Electric Power (kW)<\/td>8\/12<\/td><\/tr>
Rated Current (Amp)<\/td>14\/20.87<\/td><\/tr>
DG Size L x W x H (mm)<\/td>1750 x 900 x 1221<\/td><\/tr>
DG Weight approx. (Kg)<\/td>676<\/td><\/tr>
Fuel Tank Capacity (Ltr)<\/td>55<\/td><\/tr>
Battery Capacity (AH)<\/td>90<\/td><\/tr>
System DC Voltage (Volt)<\/td>12<\/td><\/tr>
ENGINE SPECIFICATIONS<\/u><\/strong><\/td><\/tr>
Engine Model<\/td>AL2CDG1<\/strong><\/td><\/tr>
Engine Rated kW\/Engine Rated HP<\/td>15.6\/21<\/td><\/tr>
Aspiration<\/td>NA<\/td><\/tr>
No. of cylinders & configuration<\/td>2, In line<\/td><\/tr>
Bore x Stroke (mm)<\/td>104 x 113<\/td><\/tr>
Displacement (Ltr)<\/td>1.92<\/td><\/tr>
Compression ratio<\/td>18.5 +0.5 : 1<\/td><\/tr>
Lube Oil Capacity approx. (Ltr)<\/td>6<\/td><\/tr>
Coolant Capacity approx. (Ltr)<\/td>10<\/td><\/tr>
Governing Class<\/td>A1<\/td><\/tr>
Governer Used<\/td>Mechanical<\/td><\/tr>
Oil Change Period<\/td>600 Hrs or 1 Year<\/td><\/tr>
Lube Oil specification<\/td>Gulf Leypower XLL Diesel Engine Oil<\/td><\/tr>
Alternator<\/td>Brushless, Single Bearing, IP23, Class H Insulated, 50 Hz, Voltage Regulation \u00b1 0.5%, 0.8PF Lag<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n

<\/p>\n\n\n\n

<\/p>\n\n\n\n

GENERATOR SPECIFICATIONS-20 kVA<\/strong><\/p>\n\n\n\n

<\/tr>
Power Rating (kVA)<\/td>20<\/td><\/tr>
Electric Power (We)<\/td>16<\/td><\/tr>
Rated Current (Amp)<\/td>27.8<\/td><\/tr>
DG Size \u2013 LxWxH (mm)<\/td>2000 X 900 X 1411<\/td><\/tr>
DG Weight approx. (Kg)<\/td>723<\/td><\/tr>
Fuel Tank Capacity (Ltr)<\/td>55<\/td><\/tr>
Battery Capacity (AH)<\/td>90<\/td><\/tr>
System DC Voltage (Volt)<\/td>12<\/td><\/tr>
ENGINE SPECIFICATIONS<\/u><\/strong><\/td><\/tr>
Engine Model<\/td>AL2CTIDG2<\/td><\/tr>
Engine Rated kW\/Engine Rated HP<\/td>25.2\/33.8<\/td><\/tr>
Aspiration<\/td>TC<\/td><\/tr>
No. of cylinders & configuration<\/td>2, In line<\/td><\/tr>
Bore x Stroke (mm)<\/td>104 x 113<\/td><\/tr>
Displacement (Ltr)<\/td>1.92<\/td><\/tr>
Compression ratio<\/td>16.5 + 0.5 : 1<\/td><\/tr>
Lube Oil Capacity approx. (Ltr)<\/td>6<\/td><\/tr>
Coolant Capacity approx. (Ltr)<\/td>12<\/td><\/tr>
Governing Class<\/td>\u04100<\/td><\/tr>
<\/td>Electronic<\/td><\/tr>
Oil Change Period<\/td>600 Hrs or 1 Year<\/td><\/tr>
Lube Oil specification<\/td>Gulf Leypower XLL Diesel Engine Oil<\/td><\/tr>
Alternator<\/td>Brushless, Single Bearing, IP23, Class H Insulated, 50 Hz, Voltage Regulation \u00b1 0.5%, 0.8PF Lag<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n

<\/p>\n\n\n\n

GENERATOR SPECIFICATIONS-25 kVA<\/strong><\/p>\n\n\n\n

<\/tr>
Power Rating (kVA)<\/td>25<\/td><\/tr>
Electric Power (kWe)<\/td>20<\/td><\/tr>
Rated Current (Amp)<\/td>34.75<\/td><\/tr>
DG Size \u2013 LxWxH (mm)<\/td>2000 x 900 x 1411<\/td><\/tr>
DG Weight approx. (Kg)<\/td>723<\/td><\/tr>
Fuel Tank Capacity (Ltr)<\/td>55<\/td><\/tr>
Battery Capacity (AH)<\/td>90<\/td><\/tr>
System DC Voltage (Volt)<\/td>12<\/td><\/tr>
ENGINE SPECIFICATIONS<\/u><\/strong><\/td><\/tr>
Engine Model<\/td>AL2CTIDG2<\/td><\/tr>
Engine Rated kW\/Engine Rated HP<\/td>25.2\/33.8<\/td><\/tr>
Aspiration<\/td>TC<\/td><\/tr>
No. of cylinders & configuration<\/td>2, In line<\/td><\/tr>
Bore x Stroke (mm)<\/td>104 x 113<\/td><\/tr>
Displacement (Ltr)<\/td>1.92<\/td><\/tr>
Compression ratio<\/td>16.5 + 0.5 : 1<\/td><\/tr>
Lube Oil Capacity approx. (Ltr)<\/td>6<\/td><\/tr>
Coolant Capacity approx. (Ltr)<\/td>12<\/td><\/tr>
Governing Class<\/td>A0<\/td><\/tr>
Governer Used<\/td>Electronic<\/td><\/tr>
Oil Change Period<\/td>600 Hrs or 1 Year<\/td><\/tr>
Lube Oil specification<\/td>Gulf Leypower XLL Diesel Engine Oil<\/td><\/tr>
Alternator<\/td>Brushless, Single Bearing, IP23, Class H Insulated, 50 Hz, Voltage Regulation \u00b1 0.5%, 0.8PF Lag<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n

<\/p>\n\n\n\n

GENERATOR SPECIFICATIONS-30 kVA<\/strong><\/p>\n\n\n\n

<\/tr>
Power Rating (KVA)<\/td>30<\/td><\/tr>
Electric Power (KWe)<\/td>24<\/td><\/tr>
Rated Current (Amp)<\/td>41.74<\/td><\/tr>
DG Size LxWxH (mm)<\/td>2000 x 900 x 1411<\/td><\/tr>
DG Weight approx. (Kg)<\/td>744<\/td><\/tr>
Fuel Tank Capacity (Ltr)<\/td>55<\/td><\/tr>
Battery Capacity (AH)<\/td>90<\/td><\/tr>
System DC Voltage (Volt)<\/td>12<\/td><\/tr>
ENGINE SPECIFICATIONS<\/u><\/strong><\/td><\/tr>
Engine Model<\/td>AL2CTIDG1<\/td><\/tr>
Engine Rated kW\/Engine Rated HP<\/td>28.4\/38<\/td><\/tr>
Aspiration<\/td>TC<\/td><\/tr>
No. of cylinders & configuration<\/td>2, In line<\/td><\/tr>
Bore x Stroke (mm)<\/td>104 x 113<\/td><\/tr>
Displacement (Ltr)<\/td>1.92<\/td><\/tr>
Compression ratio<\/td>16.5 + 0.5 : 1<\/td><\/tr>
Lube Oil Capacity approx. (Ltr)<\/td>6<\/td><\/tr>
Coolant Capacity approx. (Ltr)<\/td>13<\/td><\/tr>
Governing Class<\/td>\u04100<\/td><\/tr>
Governer Used<\/td>Electronic<\/td><\/tr>
Oil Change Period<\/td>600 Hrs or 1 Year<\/td><\/tr>
Lube Oil specification<\/td>Gulf Leypower XLL Diesel Engine Oil<\/td><\/tr>
Alternator<\/td>Brushless, Single Bearing, IP23, Class H Insulated, 50 Hz, Voltage Regulation \u00b1 0.5%, 0.8PF Lag<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n