Warning: The magic method Theme_Demo_Import::__wakeup() must have public visibility in /home/spacehos/public_html/prasha/wp-content/plugins/theme-demo-import/inc/class-tdi-main.php on line 74
DG 5Kva-30Kva – prasha

DG 5Kva-30Kva

GENERATOR SPECIFICATIONS-5 kVA

Power Rating (KVA)5
Electric Power (kWe)4
Rated Current (Amp)20.85
DG Size L x W x H (mm)1050 x 580 x 900
DG Weight approx. (kg)290
Fuel Tank Capacity (Ltr)12
Battery Capacity (AH)35
System DC Voltage (Volt)12
ENGINE SPECIFICATIONS
Engine ModelAL418DG1
Engine Rated kW/Engine Rated HP5.5/7.5
AspirationNA
No. of cylinders & configurationSingle, Vertical
Bore x Stroke86 x 72
Displacement0.418
Compression ratio20:01
Lube Oil Capacity approx. (Ltr)1.65
Coolant Capacity approx. (Ltr)Air Cooled
Governing ClassA1
Governer UsedMechanical
Oil Change Period150 Hrs or 3 Month
Lube Oil specificationGulf Leypower XLL Diesel Engine Oil
Alternator230 V**

GENERATOR SPECIFICATIONS-10/15 kVA

Power Rating (KVA)10/15
Electric Power (kW)8/12
Rated Current (Amp)14/20.87
DG Size L x W x H (mm)1750 x 900 x 1221
DG Weight approx. (Kg)676
Fuel Tank Capacity (Ltr)55
Battery Capacity (AH)90
System DC Voltage (Volt)12
ENGINE SPECIFICATIONS
Engine ModelAL2CDG1
Engine Rated kW/Engine Rated HP15.6/21
AspirationNA
No. of cylinders & configuration2, In line
Bore x Stroke (mm)104 x 113
Displacement (Ltr)1.92
Compression ratio18.5 +0.5 : 1
Lube Oil Capacity approx. (Ltr)6
Coolant Capacity approx. (Ltr)10
Governing ClassA1
Governer UsedMechanical
Oil Change Period600 Hrs or 1 Year
Lube Oil specificationGulf Leypower XLL Diesel Engine Oil
AlternatorBrushless, Single Bearing, IP23, Class H Insulated, 50 Hz, Voltage Regulation ± 0.5%, 0.8PF Lag

GENERATOR SPECIFICATIONS-20 kVA

Power Rating (kVA)20
Electric Power (We)16
Rated Current (Amp)27.8
DG Size – LxWxH (mm)2000 X 900 X 1411
DG Weight approx. (Kg)723
Fuel Tank Capacity (Ltr)55
Battery Capacity (AH)90
System DC Voltage (Volt)12
ENGINE SPECIFICATIONS
Engine ModelAL2CTIDG2
Engine Rated kW/Engine Rated HP25.2/33.8
AspirationTC
No. of cylinders & configuration2, In line
Bore x Stroke (mm)104 x 113
Displacement (Ltr)1.92
Compression ratio16.5 + 0.5 : 1
Lube Oil Capacity approx. (Ltr)6
Coolant Capacity approx. (Ltr)12
Governing ClassА0
Electronic
Oil Change Period600 Hrs or 1 Year
Lube Oil specificationGulf Leypower XLL Diesel Engine Oil
AlternatorBrushless, Single Bearing, IP23, Class H Insulated, 50 Hz, Voltage Regulation ± 0.5%, 0.8PF Lag

GENERATOR SPECIFICATIONS-25 kVA

Power Rating (kVA)25
Electric Power (kWe)20
Rated Current (Amp)34.75
DG Size – LxWxH (mm)2000 x 900 x 1411
DG Weight approx. (Kg)723
Fuel Tank Capacity (Ltr)55
Battery Capacity (AH)90
System DC Voltage (Volt)12
ENGINE SPECIFICATIONS
Engine ModelAL2CTIDG2
Engine Rated kW/Engine Rated HP25.2/33.8
AspirationTC
No. of cylinders & configuration2, In line
Bore x Stroke (mm)104 x 113
Displacement (Ltr)1.92
Compression ratio16.5 + 0.5 : 1
Lube Oil Capacity approx. (Ltr)6
Coolant Capacity approx. (Ltr)12
Governing ClassA0
Governer UsedElectronic
Oil Change Period600 Hrs or 1 Year
Lube Oil specificationGulf Leypower XLL Diesel Engine Oil
AlternatorBrushless, Single Bearing, IP23, Class H Insulated, 50 Hz, Voltage Regulation ± 0.5%, 0.8PF Lag

GENERATOR SPECIFICATIONS-30 kVA

Power Rating (KVA)30
Electric Power (KWe)24
Rated Current (Amp)41.74
DG Size LxWxH (mm)2000 x 900 x 1411
DG Weight approx. (Kg)744
Fuel Tank Capacity (Ltr)55
Battery Capacity (AH)90
System DC Voltage (Volt)12
ENGINE SPECIFICATIONS
Engine ModelAL2CTIDG1
Engine Rated kW/Engine Rated HP28.4/38
AspirationTC
No. of cylinders & configuration2, In line
Bore x Stroke (mm)104 x 113
Displacement (Ltr)1.92
Compression ratio16.5 + 0.5 : 1
Lube Oil Capacity approx. (Ltr)6
Coolant Capacity approx. (Ltr)13
Governing ClassА0
Governer UsedElectronic
Oil Change Period600 Hrs or 1 Year
Lube Oil specificationGulf Leypower XLL Diesel Engine Oil
AlternatorBrushless, Single Bearing, IP23, Class H Insulated, 50 Hz, Voltage Regulation ± 0.5%, 0.8PF Lag